A foot valve for a well pump is the simplest, most reliable way to keep a suction/jet pump primed: it holds water in the suction line when the pump stops, so the pump can restart without losing prime.
If your pump regularly loses prime, cycles with sputtering faucets, or you have to re-prime after sitting overnight, the practical fix is usually a correctly sized foot valve with a clean strainer, installed airtight on the bottom of the suction line.
- Match the valve size to the suction pipe (do not “step down” at the valve).
- Use a low cracking-pressure valve and a strainer that resists clogging.
- Seal every suction-side joint; even a tiny air leak can cause prime loss.
What a foot valve does in a well pump system
A foot valve is a one-way check valve installed at the end of the suction pipe down in the well (or cistern). When the pump runs, it opens and lets water flow up the suction line. When the pump stops, it closes and prevents the water column from draining back into the well.
This matters most for shallow-well jet pumps and other suction-lift configurations. Submersible pumps typically do not rely on a foot valve to maintain prime because the pump is already below the water level.
Common symptoms when the foot valve is missing or failing
- You must manually prime the pump after it sits for hours.
- The pump starts but only pushes air/water spurts before pressure builds.
- Pressure drops to zero quickly after shutdown (on systems where the gauge reflects suction-side drainback behavior).
- The pump runs longer than normal to reach cut-off pressure because it has to re-fill the suction line.
How to choose the right foot valve for a well pump
Selection is mostly about reducing suction losses and preventing clogging. The best-performing setup is usually full-size (same diameter as the suction pipe), with a durable body and a strainer appropriate for your well conditions.
Size and flow: avoid unnecessary suction restriction
On the suction side, restrictions are expensive: they increase friction loss and make priming harder. A practical rule is keep suction velocity around 2 ft/s or less where possible, which often favors a larger suction line and a full-port foot valve.
Example: If you want about 10 gpm, a 1" suction line produces higher velocity than a 1-1/4" line, increasing losses and sensitivity to tiny air leaks. If your pump manual allows it, upsizing suction piping (and matching foot valve size) can noticeably improve stability.
Cracking pressure: lower is usually better for suction lift
“Cracking pressure” is how much differential pressure it takes to open the valve. For suction/jet pumps, a lower cracking pressure generally improves priming and reduces startup strain. If you have recurring prime issues, prioritize a foot valve designed for suction service, not a stiff spring check intended for discharge piping.
Strainer area and mesh: balance protection vs clogging
The strainer protects the valve seat and pump from debris, but a strainer that is too fine can clog quickly. A useful target is a strainer with 3–5× the open area of the suction pipe’s cross-sectional area to keep intake velocity low and reduce clogging risk.
| Material | Strengths | Watch-outs | Best fit |
|---|---|---|---|
| PVC | Corrosion resistant; low cost | Less impact/temperature tolerant; threads can crack if over-tightened | Clean water, moderate duty |
| Brass/Bronze | Durable; good sealing surfaces | Water chemistry can drive corrosion over time | General-purpose wells |
| Stainless steel | High corrosion resistance; long service life | Higher cost; still needs correct strainer choice | Aggressive water chemistry; long-term installs |
Installation best practices that prevent prime loss
A high-quality foot valve will still fail to “hold prime” if the suction piping leaks air or if the valve is placed where it gulps sediment. The goal is airtight suction piping and a valve location that stays submerged and clean.
Placement depth and clearance
- Keep the foot valve submerged during the lowest expected water level to avoid drawing air.
- Maintain at least 24 inches of clearance above the well bottom to reduce sand/silt ingestion.
- In sandy wells, consider raising the intake further and using a larger-area strainer to reduce localized intake velocity.
Airtight suction-side joints: where most “bad foot valves” are actually air leaks
If air enters the suction line, the water column can drain back even if the foot valve is fine. Focus on threaded fittings, unions, and any transition points. A practical standard is that the suction line should hold vacuum without decay when isolated (if you have the tools to test).
- Use a sealant appropriate for potable water and the piping material on threaded joints.
- Avoid overtightening plastic threads; use correct adapters and support the drop pipe to prevent stress.
- Prime the pump fully and confirm steady pressure rise; sputtering during prime often indicates air entry.
Practical example: why “one size smaller” causes trouble
If a 1-1/4" suction line is reduced to a 1" foot valve at the well, the smallest section governs losses. That restriction increases velocity and head loss right at the intake, making the pump more sensitive to minor air leaks and increasing the likelihood of cavitation-like noise at startup. In field terms: the system becomes harder to prime and easier to un-prime.
Troubleshooting: diagnosing foot valve vs air leak vs clog
The three most common root causes of prime loss are (1) debris preventing the foot valve from sealing, (2) suction-side air leaks, and (3) a worn valve seat/flapper. Use observable behavior to narrow it down before pulling the drop pipe.
| What you observe | Likely cause | Practical check | Action |
|---|---|---|---|
| Prime is lost after hours, especially overnight | Air leak or valve not sealing | Inspect suction fittings for seepage; listen for faint hiss; verify prime holds when isolated | Reseal joints; if airtight, pull and inspect foot valve |
| Pump starts but struggles to build pressure; long run time | Partially clogged strainer or restriction | Compare performance right after cleaning vs after days/weeks | Clean/replace strainer; consider larger strainer area |
| Sputtering air at faucets on startup | Suction air leak or low water level causing vortexing | Check water level drawdown during pumping; inspect all suction joints | Lower intake (if safe), fix leaks, ensure continuous submergence |
| Repeated prime loss soon after a new valve install | Installation issue (thread damage, misalignment, debris) | Verify drop pipe is supported; check for strained joints and over-tightened plastic threads | Rebuild stressed joints; add support and proper adapters |
A quick reality check on suction lift limits
If your static water level is deep, a foot valve cannot “solve” physics. Many shallow-well jet pumps are practical only when the suction lift (vertical distance from water level to pump) is modest. If your setup is near its lift limit, even small added losses from a restrictive foot valve, long piping runs, or clogged strainers can cause chronic prime and performance issues. In those cases, the constructive fix is often system design (shorter/larger suction line, relocating the pump, or moving to a submersible pump) rather than swapping valves.
Maintenance and replacement: keeping the foot valve reliable
Foot valves are simple devices, but they live in the worst place for debris. The most effective maintenance is keeping the strainer clear and ensuring the valve can fully seat.
Practical maintenance habits
- If your well produces sand or iron bacteria slime, inspect/clean more frequently—performance decline over weeks is a common clue.
- If priming issues appear suddenly after heavy rain or well disturbance, suspect debris on the valve seat first.
- Replace rather than “nurse along” a valve with a worn sealing surface; seat wear tends to accelerate once it starts leaking.
Typical cost and service-life expectations
Market pricing varies by size and brand, but many homeowners see typical ranges like $15–$40 for PVC, $30–$80 for brass/bronze, and $60–$150 for stainless. In clean water, service life can be several years; in sandy or biologically active wells, clogging and seat wear can shorten life significantly. The best predictor of longevity is not the label—it is well conditions plus proper installation and sealing.
Bottom line: the simplest “do this” checklist
For most shallow-well and suction/jet setups, the best results come from a full-size, low-restriction foot valve installed with a strainer that stays clear and suction joints that are truly airtight.
- Select a foot valve that matches the suction pipe diameter and is intended for suction service.
- Prioritize low cracking pressure and a strainer with ample open area to reduce clogging.
- Install it well below the lowest water level and at least 24 inches above the bottom to avoid sediment.
- If prime loss persists, test for suction air leaks before blaming the valve.